Heavy duty ballasts for low pressure mercury lamps

  • Encapsulated electromagnetic ballasts, dedicated especially for harsh and corrosive environments
  • Screw terminal blocks
  • For use in combination with parallel ignitors for HPI lamps
  • Winding temperature Tw =130°C

Products

Product name Ordering code Power Lamps Thermal
protection
Energy
Efficiency
Class
Dimensions
Lamp current Delta T Tw Weight Capacitor [mm]
[A] [°C] [°C] [kg] [μF] A1 A2 B1 C1 D1
BHL 250 L40-A2 230V 50Hz HD2-126 9136 039 20446 250 HPL/HPI 2.13/2.15 85 no 130 1.84 18 A2 126 107 81 66 6.2